• Welcome to Lyssos Enterprises!
  • +30 210 7106060
  • 6-8, Efklias Str, Piraeus, 185 38, Greece

Ventis Pro5 Multi-Gas Monitor

GAS DETECTION MEETS CONNECTED SAFETY

 

Connected safety is the way of the future. With the Ventis® Pro5 Multi-Gas Monitor, you have the flexibility to choose how you want your teams to connect. Whether you want peer-to-peer alarm sharing, remote live monitoring with location details, or a combination of the two, the Ventis Pro5 has you covered. In addition to gas detection, the Ventis Pro5 features a dedicated man-down alarm, panic button, and custom on-screen messages making it easy for workers to communicate and operate.

 

  1. Detect up to five gases simultaneously using flexible sensor configurations
  2. Endure the harshest conditions thanks to IP68 rating backed by a Guaranteed for Life™ warranty
  3. Improve team and site safety by locally sharing alarms and gas readings between Ventis Pro5 gas monitors
  4. Increase situational awareness by receiving real-time location and alarm data directly from Ventis Pro5 gas monitors to iNet Now live monitoring software
  5. Track assets and people in real-time with iAssign® technology
  6. Transition seamlessly from personal monitoring to confined space entry and eliminate the need for extra equipment by using the Ventis® Slide-on Pump
  7. Available with or without an integral pump

 

Description

Detect up to five gases: Rely on flexible sensor options to detect combustible and toxic gases in a broad range of settings, making the Ventis Pro Series ideal for both personal protection and confined space applications.

Simplify gas detection for your users: Create custom start-up messages to communicate safety information to your team, see gas readings and alarms from connected peers using LENS Wireless, acknowledge low gas levels, and receive written instructions when an instrument goes into alarm.

React in emergency situations: Know when a worker is in distress or has lost consciousness thanks to a dedicated panic button and man-down alarm. Panic and man-down alarms will be relayed to other Ventis Pros in your group using LENS Wireless.

Track instruments and alarms: Address recurring alarms and improve asset management by assigning users and sites to each gas monitor in real time using iAssign™ Technology.

Depend on a rugged design:  Keep your instruments in the field, not the shop, thanks to an IP68 rating for dust and water ingress and a rugged overmold that is Guaranteed for Life™ .

Upgrade with ease: Don’t buy all new accessories. Most of your Ventis™ MX4 accessories are compatible with the Ventis Pro Series.

Technologies

Upgrade with ease: Don’t buy all new accessories. Most of your Ventis™ MX4 accessories are compatible with the Ventis Pro Series.

 

LENS Wireless  is the first gas detection solution that allows personal monitors and area monitors to share gas readings and alarms with one another. Now when a gas hazard, man-down, or panic situation causes an instrument to alarm, all peers in the connected group will instantly be notified of the hazard and the person in danger. When seconds matter, you can rely on help from workers nearby, rather a call center hundreds of miles away.
DualSense Technology uses redundant sensors to determine the concentration of the target gas in the atmosphere and reduce the risk of instrument failure. Two sensors of the same type in one gas detector help to give you the most accurate gas reading. iAssign Technology uses Near Field Communication (NFC) and Bluetooth technology to assign workers and locations to Ventis® Pro Series gas detectors. Access to user and site data allows you to locate problem areas across your facility, stay compliant with clear and accurate record keeping, and alert workers when they enter restricted areas. iAssign provides a more complete picture of what’s happening across a worksite, enabling safety managers to take action to prevent repeated hazards.

Common Configurations

Common Configurations

 

Ventis Pro5

PART NUMBER DESCRIPTION
VP5-KJ5Y2111ywz Ventis Pro5 with pump – LEL (Pent), CO/H2S, SO2, O2, Extended Li-ion, Desktop Charger, Safety Orange
VP5-KJ4Y4101ywz Ventis Pro5 – LEL (Pentane), CO/H2S, NO2, O2, Slim Extended Li-ion, Desktop Charger, Safety Orange
VP5-KJ6Y2110ywz Ventis Pro5 with pump – LEL (Pent), CO/H2S, NH3, O2, Extended Li-ion, Desktop Charger, Black
VP5-U12Y2110ywz Ventis Pro5 with pump – CO2/LEL IR, CO, H2S, O2, Extended Li-ion, Desktop Charger, Black
y = Agency Certification: 1 = UL/CSA, 2 = ATEX/IECEx, 3 = MSHA, 9 = INMETRO
w = Wireless: 0 = Non-wireless, 1 = Wireless
z = Language for included Reference Guide: 1 = EN, 2 = FR, 3 = ES, 4 = DE, 5 = IT, 6 = DU, 7 = PT, A = PL

 

Ventis Pro4

PART NUMBER DESCRIPTION
VP4-K12Y4101ywz Ventis Pro4 – LEL (Pentane), CO, H2S, O2, Slim Extended Li-ion, Desktop Charger, Safety Orange
VP4-K12Y2110ywz Ventis Pro4 with pump – LEL (Pent), CO, H2S, O2, Extended Li-ion, Desktop Charger, Black
VP4-K52Y4101ywz Ventis Pro4 – LEL (Pentane), SO2, H2S, O2, Slim Extended Li-ion, Desktop Charger, Safety Orange
VP4-K14Y4101ywz Ventis Pro4 – LEL (Pentane), CO, NO2, O2, Slim Extended Li-ion, Desktop Charger, Safety Orange
VP4-K1BY4101ywz Ventis Pro4 – LEL (Pentane), CO, HCN, O2, Slim Extended Li-ion, Desktop Charger, Safety Orange
VP4-K1BY2111ywz Ventis Pro4 with pump – LEL (Pent), CO, HCN, O2, Extended Li-ion, Desktop Charger, Safety Orange
y = Agency Certification: 1 = UL/CSA, 2 = ATEX/IECEx, 3 = MSHA, 9 = INMETRO
w = Wireless: 0 = Non-wireless, 1 = Wireless
z = Language for included Reference Guide: 1 = EN, 2 = FR, 3 = ES, 4 = DE, 5 = IT, 6 = DU, 7 = PT, A = PL

Accessories

PART NUMBER DESCRIPTION
18109327-ABC DSX™ Docking Station for Ventis

  1. – DSX Mode:
    0 = DSX Standalone
    1 = DSXi Cloud-connected
    2 = DSX-L Local Server
  2. – Number of Gas Inlet Ports: 
    3 = 3 Ports
    6 = 6 Ports
  3. – Power Cord Type:  1 = North America, 2 = EU, 3 = AUS, 4 = UK
18108631-AB V•Cal™ Calibration Station
A = Instrument Type: 0 = Ventis, 1 = Ventis with Pump
B = Power Cord: 0 = US, 1 = UK, 2 = EU, 3 = AUS, 4 = ITA, 5 = DEN, 6 = SWZ
18107664-ABC V•Cal™ 6 Unit Calibration Station
AB = Number of Ventis (A) and Ventis with Pump(B) Instruments
06 = 0 Ventis and 6 Ventis with Pump
33 = 3 Ventis and 3 Ventis with Pump
60 = 6 Ventis and 0 Ventis with Pump
C = Power Cord: 0 = Universal with US, UK, EU, AUS Plug Adapters
18107763 Serial data dot matrix printer for V•Cal™ – 5 volts powered by the Cal Station

Specifications

WARRANTY

Guaranteed for Life. Warranted for as long as the instrument is supported by Industrial Scientific Corporation (excludes sensors, batteries, and filters). O2, LEL, CO, and H2S sensors warranted for three years. All other sensors warranted for two years. Pumps and batteries are warranted for two years.

KEYPAD

Two buttons for operation. Dedicated panic button.

DATA LOG

At least 3 months at 10-second intervals

EVENT LOGGING

60 alarm events

INGRESS PROTECTION

IP68 (submersion at 1.5 meters for 1 hour)

CASE MATERIAL

Polycarbonate with protective rubber overmold

DIMENSIONS

104 x 58 x 36 mm (4.1 x 2.3 x 1.4 in) without pump

172 x 67 x 65 mm (6.8 x 2.6 x 2.6 in) with pump

WEIGHT

200 g (7.05 oz), typical without pump

390 g (13.76 oz), typical with pump

TEMPERATURE RANGE

-40° C to 50 °C (-40° F to 122° F)**

HUMIDITY RANGE

15%-95% Non-condensing

WIRELESS

Optional LENS™ Wireless, proprietary mesh network

Frequency: ISM license-free band (2.405 – 2.480 GHz)

Max Peers: 25 devices per network group

Range: 100 m (300 ft) line of sight, face-to-face

Encryption: AES-128

Approvals: FCC Part 15, IC, CE/RED, others†

DISPLAY/READOUT

Backlit liquid crystal display (LCD)

POWER SOURCE/RUN TIME

Rechargeable slim extended lithium-ion battery

(18 hours typical @ 20 ºC) without pump

Rechargeable lithium-ion battery pack with LEL

(12 hours typical @ 20 ºC) without pump

Rechargeable extended-range lithium-ion battery pack with LEL

(23 hours typical @ 20 ºC) without pump
(18 hours typical @ 20 ºC) with pump

 Rechargeable lithium-ion battery pack with IR

(36 hours typical @ 20 ºC) without pump

Rechargeable extended-range lithium-ion battery pack with IR

(72 hours typical @ 20 ºC) without pump
(32 hours typical @ 20 ºC) with pump

ALARMS

Four visual alarm LEDs (two red, two blue);

95 decibel (dB) audible alarm at a distance of 10 cm (3.94 in);

Vibration alarm

SUPPLIED WITH MONITOR

Calibration Cup (Ventis), Sample Tubing (Ventis with pump), Reference Guide

REFERENCE GUIDE LANGUAGE

English (1), French (2), Spanish (3), German (4), Italian (5), Dutch (6), Portuguese (7), Polish (A)

SENSORS

Combustible Gases/Methane – Catalytic Bead
O
2, CO, CO/Hlow, H2S, HCN, NH3, NO2, PH3, SO2– Electrochemical

CH4, CO2/LEL, CO2/CH4 – Infrared


MEASURING RANGES

Catalytic Bead

Combustible Gases: 0-100% LEL in 1% increments

Methane (CH4): 0-5% of vol. in 0.01% increments

Electrochemical

Ammonia (NH3): 0-500 ppm in 1 ppm increments

Carbon Monoxide (CO): 0-2,000 ppm in 1 ppm increments

Carbon Monoxide (CO/Hlow): 0-1,000 ppm in 1 ppm increments

Carbon Monoxide/Hydrogen Sulfide: CO: 0-1,500 ppm in 1 ppm increments

Hydrogen Sulfide (H2S): 0-500 ppm in 0.1 ppm increments

Hydrogen Cyanide: 0-30 ppm in 0.1 ppm increments

Nitrogen Dioxide (NO2): 0-150 ppm in 0.1 ppm increments

Oxygen (O2) (Standard/Long-Life): 0-30% of vol. in 0.1% increments

Phosphine (PH3): 0-10 ppm in 0.01 ppm increments

Sulfur Dioxide (SO2): 0-150 ppm in 0.1 ppm increments

Infrared

Methane (CH4): 

0-5% vol in 0.01% increments

5-100% vol in 0.1% increments

Carbon Dioxide/Combustible: 

CO2: 0-5% vol in 0.01% increments

LEL: 0-100% LEL in 1% increments

Carbon Dioxide/Methane:

CO2: 0-5% vol in 0.01% increments

CH4: 0-5% vol in 0.01% increments

CH4: 5-100% vol in 0.1% increments

CERTIFICATIONS

ANZEx:

Ex ia I Ma/Ex ia IIC T4 Ga, -40 °C ≤ Ta ≤ 50 °C
Ex d ia I Mb/Ex d ia IIC T4 Gb IR sensor,
-20 °C ≤ Ta ≤ 50 °C IR sensor

ATEX:

Equipment Group and Category II 1G,
Ex ia IIC, Ga, T4 Equipment Group and Category II 2G,
Ex d ia IIC, Gb, T4, IR sensor

China CPC:

CPA 2017-C103

China Ex:

Ex ia IIC T4 Ga, -40 °C ≤ Ta ≤ 50 °C;
Ex d ia IIC T4 Gb IR sensor,
-20 °C ≤ Ta ≤ 50 °C IR sensor

CSA:

Cl I, Div 1, Gr A-D, T4;
Cl I, Zone 1, Ex d ia IIC, T4 | C22.2
No. 152 for % LEL reading only

IECEx:

Cl I, Zone 0, Ex ia IIC, Ga, T4;
Cl I, Zone 1, Ex d ia IIC, Gb, T4, IR sensor

InMetro:

Ex ia IIC T4 Ga, -40 °C ≤ Ta ≤ 50 °C
Ex d ia IIC T4 Gb IR sensor,
-20 °C ≤ Ta ≤ 50 °C IR sensor

MSHA:

30 CFR Part 22; Permissible for underground mines

PA-DEP:

BFE46-12 Permissible for PA Bituminous underground mines

UL:

Cl I, Div 1, Gr A-D, T4; Cl II, Div 1, Gr E-G,
T4 Cl I, Zone 0, AEx ia IIC, T4;
Cl I, Zone 1, AEx d ia II C, T4, IR sensor

* These specifications are based on performance averages and may vary by instrument.

** Operating temperatures above 50 °C (122 °F) may cause
reduced instrument accuracy. Operating temperatures below
-20 °C (-4 °F) may cause reduced instrument accuracy and affect
display and alarm performance. See Product Manual for details.

† See www.indsci.com/wireless-certifications for country-specific wireless approvals and certifications.

Downloads

VentisPro_ProductGuide_EN
VentisPro_OrderingGuide_EN
Ventis-Pro-Declaration-of-Conformity-Charger-Datalink-17158279
Ventis-Pro-Declaration-of-Conformity-17157420
Release Notes Summary – Ventis Pro Series
LENS_SpecSheet_EN (1)
Beacon_SpecSheet_EN
AN_VentisPro_SlimExtended_EN
AN_VentisPro_Sensors_EN
AN_VentisPro_Pro5Sensor_EN
AN_VentisPro_LongLifeSensor_EN_V2
AN_VentisPro_iAssign_EN
AN_VentisPro_Alarms_EN
AN_iAssignBeacons_EN
17156830-1-Ventis-Pro-Product-Manual-EN