• Welcome to Lyssos Enterprises!
  • +30 210 7106060
  • 6-8, Efklias Str, Piraeus, 185 38, Greece

UPG

DEZEGA recommends using the UPG leak tester to test regularly for leak tightness on waist-worn self-contained self-rescuers.

The operating principle of the leak tester is based on over-pressurizing (to a defined value) an airtight chamber where a self-rescuer has been placed in advance.

Description

The use of the UPG is mandatory when a SCSR is registered, undergoing technical inspections, and also when a SCSR is in operation.


CHARACTERISTICS AND ADVANTAGES

  • Quick check for leaks

  • Easy installation and regular maintenance

  • Complete with oil pressure gauge

  • Availability of calibration tools

Features

Chamber working pressure, kPa

5 ± 0,2

Pressure measurement range, kPa

3,8-5,3

Manometer relative error, %

1,6

Dimensions, mm

263 × 450 × 321

Weight, kg

8