• Welcome to Lyssos Enterprises!
  • +30 210 7106060
  • 6-8, Efklias Str, Piraeus, 185 38, Greece

CheckUp

DEZEGA CheckUp breathing equipment test set checks the parameters of compressed air and compressed oxygen breathing apparatuses, as well as self-contained panoramic mask and resuscitators. The test set should be used by the departments that operate or service BA.The test set complies with Directive 2014/30/EU, Directive 2014/35/ЕU, EN 61326-1:2013, TR CU 020/2011, TR CU 004/2011.

Description

DEZEGA Checkup will check :

  • self-contained breathing apparatuses compliant with EN 145:1997, DSTU EN 145, DSTU 3856, GOST R 12.4.253, GOST R 53256, TR CU 019/2011 or equivalent (Р 30 and its modifications, Р-70, BG 4, etc);
  • self-contained paniramic masks compliant with EN 136:1998, DSTU EN 136, GOST R 53257 or equivalent;
  • resuscitators of the GS-10 type;
  • separate components of the breathing equipment.

Features

Pressure measuring range (positive-negative), kPa from – 2,8 to 6,8
Limits of permissible overpressure-dilution measurement error, % of range measurements  

 

±0,5

Range of indications of flow through the oxygen channel, dm3/min from 0 to 6
Range of measurements of flow through the oxygen channel, dm3/min from 1 to 6
Limits of permissible reduced error per channel oxygen, % of the upper limit of measurement

in the range from 1 to 3.0 dm3/min
in the range above 3.0 to 6.0 dm3/min

 

±2,0

±3,0

Range of indications of an expense on the air channel, dm3/min from 0 to 150
Range of measurements of an expense on the air channel, dm3/min from 10 to 150
Limits of permissible reduced error per channel air flow, % of the upper limit of measurement ±5,0

 

Operation mode

Duration of one cycle, min

  • Break between cycles, min, not less than
  • Continuous operation time in multiple cyclic mode, h (per day), not more than
Cyclical

from 5 to 30

5

7

Power supply parameters:

  • AC voltage, V
  • AC frequency, Hz
  • power consumption, V∙A, not more than
 

220±15%

50±5

230

Overall dimensions, mm, not more than

  • height
  • length
  • width
 

220

460

480

Weight (without adapters), kg, not more than 15
Operating conditions:

  • ambient temperature, °С
  • relative humidity (without condensation), %
  • Atmospheric pressure, kPa
 

from +15 to +25

from 30 to 80

from 84 to 106,7

Service life from the date of manufacture, years 9
Mean time to failure, h 16240

Downloads

CHECK UP USER MANUAL

CHECK UP EU CERTIFICATE

CHECK UP LEAFLET EN